Home
News
Products
Services
Contact Us
Partners
Legal
Site Map

VRM-A2615

The VRM-A2615 is a 6-channel Pt100 Measurement Board.

1). 6 channel platinum resistance thermometer (Pt100), measurement is possible. As soon as the power is turned on and/or as soon as the hardware is reset, default settings start temperature measurement.

2). Because a terminal block type two-piece connector is used, it is possible to remove just the terminal block and change the board without removing each of the thermocouple screw clamps from the terminal block. The terminal block does not prevent the removal of the adjacent board.

3). Can be set to take the moving average of the last four lots of A/D conversion values and calculate the temperature conversion values. Because it is the moving average, the most recent temperature conversion values, averaged for each sampling, can be obtained.

4). Disconnection of cables including thermocouples can be detected for each input channel. When disconnection is detected, an interrupt can be issued to the CompactPCI bus.



Features:

Measurement method: 3 wire system
Connectable resistance thermometer: Pt1100
Temperature input range: -50°C to +100°C
Temperature conversion values:
16-bit code binary format (minus numbers: two’s complement)
-500 to +1000 (value to first decimal place x 10)
Resolution: 0.1°C
Overall accuracy: +0.75°C *1
Input bandwidth: Apx. 25Hz (-3dB)
Conversion rate: Apx. 100Hz for each channel
Sampling rate: Apx. 100Hz for all channels *2
No. of temperature input points: 6 points
Pt100 sense current: 1mA
Isolation method:
Between Pt100 input and CompactPCI bus system: Photo-coupler isolation
Between Pt100 input channels: No isolation
Disconnection detection: Yes (independent for each channel)
Connection terminal: 6-pint terminal block
Recommended wire size: 1.5mm2 or less
Power Requirements: DC5V +5%, Typ. 0.62A
Board size: Single height (3U), single width (4HP)
Weight: 160g
Environmental Specifications:
Operating temperature range: 0 to 50°C
Storage temperature range: -10 to 60°C
Operating humidity range: 10 to 90% RH (non-condensing)
Storage humidity range: 10 to 90% RH (non-condensing)
Operating atmosphere: Minimum dust, must be free of corrosive gases
*1– accuracy does not include accuracy and temperature characteristics for external components (platinum resistance thermometer, etc), not included
*2– equipped with one A/D converter for al Pt100 input channels


Request a Quote for Ordering Info

Read the Datasheet

← Return to previous page

Johnstown Professional Complex
55 East Main Street, Suite 310
Johnstown, NY 12095 USA
Phone Number: 518.762.1288
Fax Number: 518.762.4399

This website may contain inaccuracies or typographical errors; V Rose Microsystems, Inc. will try to maintain the website's accuracy. V Rose Microsystems, Inc. may make improvements and/or changes in the products and services described in this site at any time without notice.
... ...
All Rights Reserved V Rose Microsystems, Inc. 2002-2008